Load testing anchor

Load testing anchor

Load testing anchor
Load testing anchor

The load testing anchor is used to verify bearing capacity of already installed anchorage points in lift shaft or machine room ceilings.
The following loads can be verified:

Load testing anchor
Load testing anchor

Instructions: first, the chosen load testing anchor is fixed to the anchorage point with the above specified loop (1). Afterwards the applicable force has to be imposed (2) to break the material at the predetermined point. The on site attachments must be sufficiently dimensioned.

Requirements

The capacity of the anchorage point is verified if it passes the test. The load testing anchor cannot verify the capacity or the quality of the lift shaft or machine room ceiling itself. The manufacturer is only liable for the load testing anchor itself.

The user and the company which mounted the parts carry the liability for the fixing of the anchorage point as well as the force transmission into the structural part.

Product overview
Item No. Carrying capacity
ca. (kg)
Breaking of the load
testing anchor at the
predetermined location
at about ca. (kg)
01303050001 up to 500 600
01303100001 up to 1.000 1.500
01303130001 up to 1.300 2.000
01303200001 up to 2.000 3.000
01303260001 up to 2.600 4.000