Ceiling anchor points

Ceiling anchor points

Machinery Directive 2006/42/EC [4] of the European Parliament and the Council of May 17, 2006, forms the basis for the development of slings and for the verification of the required levels of safety. All slings have a fixed rope loop which is secured so that it cannot come loose.

PFEIFER lifting loop LSF for insertion into formwork

PFEIFER lifting loop LSF
PFEIFER lifting loop LSF

Machinery Directive 2006/42/EC [4] of the European Parliament and the Council of May 17, 2006, forms the basis for the development of slings and for the verification of the required levels of safety. All slings have a fixed rope loop which is secured so that it cannot come loose.

PFEIFER lifting loop LSF for insertion into formwork This consists of an anchor approved for permanent fixing in concrete and a cover plate. The LSF is installed flush-mounted in the formwork prior to concreting.

Features: Prior to concreting

Requirements

Proof of sufficient carrying capacity of the lifting device in connection with the shaft ceiling (thickness, reinforcement and load transfer) must be demonstrated by a responsible planner. Moreover, the where-installed and where-used lists supplied with the product must be observed.

Machinery Directive 2006/42/ EC [4] of the European Parliament and the Council of May 17, 2006, forms the basis for the development of slings and for the verification of the required levels of safety. All slings have a fixed rope loop which is secured so that it cannot come loose.

Product overview
Item No. Carrying capacity
(max) kN
Carrying capacity
(max) kg
Ceiling thickness
(min) mm
43103006001 6 600 mind. 140
43103012501 12,5 1.250 mind. 170
43103022501 22,5 2.250 mind. 250
Certified by TÜV Süd

 

PFEIFER lifting loop LSG for through-type mounting

PFEIFER sling LSG
PFEIFER sling LSG

This consists of a through-type element. The sling LSG is used after concreting, e.g. if renovation work is required. For the assembly, a hole must be completely drilled through the ceiling in the elevator shaft. The anchor is pushed through from below and then fully mounted.

Features: Subsequent installation

Requirements

Proof of sufficient carrying capacity of the lifting device in connection with the shaft ceiling (thickness,reinforcement and load transfer) must be demonstrated by a responsible planner. Moreover, the where-installedand where-used lists supplied with the product must be observed.

Proofs for concrete and steel Calculatory proof of the metallic safelies is not sufficient in order to prove a conclusive safety concept for load hooks. Many fastening points available on the market supply precisely this proof alone, however, and stop at the transition to the concrete structure.

However, it is frequently precisely the anchorage in the concrete that is the critical point. Here two standard worlds have to be combined and the global safelies proven. ln all cases this is guaranteed in the case of PFEIFER products using anchoring means approved by the building authoritles.

Product overview
Item No. carrying capacity
(max) kN
carrying capacity
(max) kg
ceiling thickness
maximum (mm)
43101005001 5 500 max. 482
43101010001 10 1.000 max. 476
43101017501 17,5 1.750 max. 483
43101025001 25 2.500 max. 490
43101040001 40 4.000 max. 492
Certified by TÜV Süd

 

PFEIFER lifting loop LSP for dowel mounting

PFEIFER sling LSP
PFEIFER sling LSP

This consists of one anchoring element. The LSP is used after concreting, e.g. if renovation work is required. It is attached to the ceiling from below using newly affixed dowels. A drilled hole/recess must be created in a suitable place on the underside of the shaft ceiling to enable the sinking in of the case which protrudes from the back. 

Features: Subsequently to concreting

Requirements

Proof of sufficient carrying capacity of the lifting device in connection with the shaft ceiling (thickness,reinforcement and load transfer) must be demonstrated by a responsible planner. Moreover, the where-installedand where-used lists supplied with the product must be observed

Product overview
Item No. carrying capacity
(max) kN
carrying capacity
(max) kg
ceiling thickness (mm)
43102010001 10 1.000 *
43102017501 17,5 1.750 *
43102025001 25 2.500 *
43102040001 40 4.000 *

* Must be calculated depending on the dowel used.

Certified by TÜV Süd

 

PFEIFER lifting loop LSV for recessed installation

PFEIFER sling LSV
PFEIFER sling LSV

This consists of an anchor approved for permanent fixing in concrete and a protective box. The LSV is installed flush-mounted in the formwork prior to concreting. The box is then easily nailed to the formwork and opened following concreting so that the sling can be folded out.

Features: Without any perforation of the formwork

Requirements

Proof of sufficient carrying capacity of the lifting device in connection with the shaft ceiling (thickness,reinforcement and load transfer) must be demonstrated by a responsible planner. Moreover, the where-installedand where-used lists supplied with the product must be observed.

Product overview
Item No. carrying capacity
(max) kN
carrying capacity
(max) kg
Deckenstärke
mm
43104005001 5 500 mind. 135
43104010001 10 1.000 mind. 155
43104017501 17,5 1.750 mind. 180
Certified by TÜV Süd

 

PFEIFER load eye for the temporary attachment of loads

Approvals

PFEIFER lifting eyes are attachment points for the temporary attachment of material loads during assembly or maintenance work. They are intended to be used for the flat installation in ceilings made of reinforced concrete. The attachement points can be used either for the temporary attachement of material loads or for personal safety equipment. It is not permitted to use for both purposes simultaneously.

Features: Prior to concreting

Requirements

Proof of sufficient carrying capacity of the lifting device in connection with the shaft ceiling (thickness,reinforcement and load transfer) must be demonstrated by a responsible planner. Moreover, the where-installedand where-used lists supplied with the product must be observed.

Product overview
Item No. carrying capacity
(max) kN
carrying capacity
(max) kg
ceiling thickness
minimum mm
43105020001 20 2.000 mind. 150 (130*)
43105040001 40 4.000 mind. 220 (200*)

* If the anchor plate is coated with a suitable corrosion protection system, a reduced ceiling thickness of130 mm or 200 mm can be applied. The required proof must be demonstrated by the user.